INVESTIGATIVE WALL MONITORING
Some examples of where we monitor and which sensors we use for certain wall types.
Historic Masonry Wall Monitoring: Research
Parameters Measured
-
Interior air conditions
-
Moisture level in: plaster, interior brick, brick (inner and outer), sandstone (inner, outer and upper)
-
Condensation level in: cavity air space
-
Differential pressure: interior and exterior air gap
-
External crack movement tracking
Historic Masonry
Wall Monitoring: Basic
Historic Masonry
Wall Monitoring: Research
Wood Wall Monitoring: Commercial
Parameters Measured
​
-
Interior air conditions
-
Moisture level in: plaster, interior brick, brick (inner and outer), sandstone (inner, outer and upper)
-
Condensation level in: cavity air space
-
Differential pressure: interior and exterior air gap
-
External crack movement tracking
Wood Wall Monitoring: Research
Parameters Measured
​
-
Sheeting moisture content/condensation
-
Wall temperature profile: External wetting potential/siding
-
MC differential pressure across assembly effects of solar influence on temperature and hydrothermal performance.
-
Transient R-Value, measuring energy transfer through assembly
-
Exterior conditions related to Interior conditions